Hipot RPT-4632 Smart Substation Relay Protection Test System
$40
$48.4
RPT-4632 relay protection tester adopts modular design, with high-precision current and voltage amplifier modules, higher output accuracy, better stability, small size, light weight, rich test functions, etc. It uses a 9-inch high-definition touch LCD screen and full touch screen operation without buttons, making the operation more convenient and efficient. The instrument integrates conventional relay protection test, digital relay protection test, digital-analog hybrid relay protection test, merged unit test, intelligent terminal test, message analysis measurement, SCD file parsing and comparison, MMS related services and cloud testing functions, which can fully meet the test requirements of all types of relay protection and automatic devices in power plants, conventional substations, smart substations and new generation substations.Product Features:-• The current and voltage output accuracy of 0.05, meets the requirements of merging unit testing.• Multiple output channels and large amplitude: the current can output 6-phase 20A or 3-phase 40A, and the voltage can output 4-phase 300V.• 9-inch LCD touch screen, full touch screen operation, convenient and fast operation.• Linux operating system, it runs stably compared with Windows CE operating system.• Powerful abnormal working condition alarm function, completing voltage source short circuit, current source open circuit, overheating and signal distortion detection through pure hardware.• Digital-analog mixed output mode meets the protection device testing requirements of "analog quantity GOOSE".• Gigabit port configuration meets the requirements of gigabit message reception and transmission.• Powerful SV and GOOSE message analysis capabilities, with the function of message analyzer.• With SCD file comparison and SCD file graphics function.• With CID model file online reading and verification function; One-click completion of the internal CID file and SCD file consistency verification of the device.• Cross-platform application software. It has local touch screen operation or computer online operation mode.• It has cloud testing function, using cloud server technology, test templates and test cases can be downloaded and used through cloud server.• It has one-key automatic test function to meet the test requirements of factory commissioning of protection devices.• It supports the reading and verification of device protection settings, pressure plates and other information, and completes regular on-site verification.• It has optical power measurement function.• It has data serial forwarding function.• It has GPS/BeiDou optical B code conversion function, which can be used as B code source.• It has WIFI, Bluetooth, 4G Internet of Things communication function.• It has automatic upgrade function, which can be directly upgraded using USB flash drive.• It automatically generates test reports in PDF and CSV formats, and copies and archives them through USB flash drive.Specifications:-AC CurrentSettingEach phase output current amplitude, frequency and phase are independently adjustable.Output range6×0-20A/phase, or 3×0-40A/phaseAccuracyTypical value: <±0.2mA (0A--0.2A) <±0.05%±0.1mA (0.2A--10A)<±0.1% (10A--20A)<±0.2% (20A—Imax)Guaranteed value: <0.08%rd 0.02%rg, at (0--20A)<0.15%rd 0.05%rg, at (20—Imax)Resolution1mAMax. output power Pmax6×20A/phase ≥85VA/phase, 3×40A/phase ≥160VA/phaseCurrent rise and fall time<100µsTotal harmonic distortion (THD%)Typical value: ≤0.1%(2A--Imax), ≤0.2%(0.2A--2A) Guaranteed value: ≤0.5%(0.5A--Imax)Frequency10Hz -- 1kHzAmplitude-frequency characteristicsAmplitude change ≤±0.05%--±0.5%(10Hz--1kHz)Output time<5A/phase, continuous outputAbnormal working condition alarmAutomatic detection and alarm for overheating, overload, distortion and open circuit.AC VoltageSettingEach phase output current amplitude, frequency and phase are independently adjustable.Output range4×300V/phaseAccuracyTypical value: <±1mV(0V-2V) <±0.05%(2V-Vmax)Guaranteed value: <0.08%rd 0.02%rg (0-Vmax)Resolution1 mV (0.2V--10V), 10 mV(10V-300V)Max. output power Pmax4×300V/phase ≥90VA/phaseVoltage rise and fall time<100µsTotal harmonic distortion (THD%)Typical value: ≤0.1% (2V-Vmax) Guaranteed value: ≤0.2% (2V--Vmax)Frequency10Hz--1kHzAmplitude-frequency characteristicsAmplitude change ≤±0.05%--±0.5%(10Hz--1kHz)Output timeOutput time Continuous output under rated conditionsAbnormal working condition alarmAutomatic detection and alarm for overheating, overload, distortion and open circuit.Current and voltage synchronization error≤10µsFrequencySine signal10Hz--1000HzAccuracy<1mHz (45Hz--65Hz) <5mHz (10Hz--45Hz, 65 Hz--450Hz)<10mHz (450 Hz--1000Hz)Resolution0.001HzOutput characteristicsCan superimpose 2-21 harmonics of any amplitude (less than rated value)Sine signal10Hz-1000HzPhasePhase angle range0-359.9°AccuracyTypical value: ≤±0.1° Guaranteed value: ≤±0.2°Resolution0.01°DC CurrentOutput range6×0-10A/phase, 3×0-20A/phaseAccuracyTypical value: <±1mA(0A-0.2A), ±0.5%(0.2A-Imax) Guaranteed value: ±5mA, at (0A-0.2A),0.3%rd 0.2%rg, at (0.2A-Imax)Resolution1mADC VoltageOutput range4×400V/phaseAccuracyTypical value: <±4mV(0V-2V), ±0.2% (2V-Vmax) Guaranteed value: ±5mV(0V-2V), <0.3%rd 0.2%rg, at(2V-Vmax)Resolution1mV (0.2V-10V), 10mV(10V-400V)Small signal analog outputChannel8 channelsOutput range0-7.07Vrms (RMS)AccuracyTypical value: <±0.1mV(0V-0.1Vrms); ±0.05%(0.1Vrms-7.07Vrms)Guaranteed value: < 0.03 % rd 0.02 % rg,at 0V-7.07 VrmsMax. output current1mAHarmonic distortion<0.05%Auxiliary DC Power Supply Output (Optional)Channel1groupOutput rangeDC 110V / 220V switchingMax. output power Pmax85W(110V), 170W(220V)Fiber optic Ethernet interfaceQuantity8 pairs, 1 pair for Gigabit networkInterface typeLC interfaceWavelength100M port: 1310nm, Gigabit port: 850nmCommunication protocolIEC61850-9-2, GOOSE, IEC1588Fiber optic serial interfaceQuantity4, 2 transmit and 2 receiveInterface typeST interfaceWavelength820nmCommunication protocolIEC60044-8, IRIG-B, PPSElectrical Ethernet interface quantity2pcsInterface typeRJ45Communication protocolMMS, TCP/IPWIFI interface quantity1Bluetooth interface quantity1USB interface quantity14G interface1 (optional)Binary In and OuputBinary In8pairsInput characteristics8 pairs of input contacts are adaptive to empty nodes or with potential; 1-4 with potential contact flip level 20~250V (DC)5-8 with potential contact flip level 9~28V (DC) Electrical isolation8 pairs of input electrical isolationImpedance coefficient of empty contact threshold3kΩ-5kΩBinary Output4pairsTypeCommon contact (response time <2ms) Fast contact (response time <100μs)DC capacityVmax: 300V (DC)/Imax: 0.3A (excluding fast output)Synchronous interfaceGPS/BeiDou interfaceBuilt-in GPS/Beidou chip, supports GPS or Beidou timingOptical B code transmissionST interface, 2pcs, multiplexed with FT3 portOptical B code receptionST interface, 1pcs, multiplexed with FT3 portPPS pulse receptionST interface, 1pcs, multiplexed with FT3 portI588 timing interfaceLC, 1 pair, multiplexed with optical network portOthersRated Voltage220V ACAllowable Voltage176V-253V ACRated frequency50HzAllowable frequency40-60HzCurrent6A(max)Screen9inch Capacitive LCD screen (touch screen)Size315mm×240mm×140mm(W×H×D)Weight< 8kgBuy Smart Substation Relay Protection Test System online in India at wholesale rates. If you have been looking for Smart Substation Relay Protection Test System dealers, your search ends here as you can get the best Smart Substation Relay Protection Test System distributors in top cities such as Delhi NCR, Mumbai, Kerala, Bengaluru, Chennai, Pune, Jaipur, Hyderabad, Nagpur and Ahmedabad.
Relay Protection Tester